Skip to main content

Using +A1 EPDs in +A2 LCAs

Updated over 2 months ago

The update to EN 15804+A2 has changed the impact indicators that are reported in EPDs. An EPD done to EN 15804+A1 will not report these required impact indicators. If your LCA is being done to the new standard, +A1 EPDs can be used in conjunction with a +A2 compliant datapoint using our "Use for A1/A2/TRACI" feature.

Use_for_A1-A2-TRACI_info.png

The below screenshot is a practical example of this, where an Ecoinvent datapoint is used for +A2 impact categories, while an EPD is used for +A1 results:

A1_and_A2_datapoints.png

The warning symbol beside the EPD is to draw attention for you to check which impact indicators it is compliant with. All Ecoinvent data is compliant with +A1, +A2 and TRACI impact indicators.

Did this answer your question?